MILLER banding
Minimally Invasive Limited Ligation Endoluminal-assisted Revision (MILLER) banding is a minimally invasive technique for banding dialysis accesses in cases of Dialysis-associated Steal Syndrome.
History
MILLER banding was first proposed in 2006 by Goel N., Miller G.A., and colleagues.[1][2]
Procedure
The fistula or graft is dissected away through a small incision. An inflated intra-luminal balloon is used to provide a solid structure (thus allowing for precise sizing of the band) and a Prolene suture is tied around the access in the region of the balloon.
References
- ↑ Goel N, Miller GA, Jotwani MC, Licht J, Schur I, Arnold WP (2006). "Minimally Invasive Limited Ligation Endoluminal-assisted Revision (MILLER) for treatment of dialysis access-associated steal syndrome.". Kidney Int. 70 (4): 765–70. doi:10.1038/sj.ki.5001554. PMID 16816841.
- ↑ Miller GA, Goel N, Friedman A, Khariton A, Jotwani MC, Savransky Y, Khariton K, Arnold WP, Preddie DC (2010). "The MILLER banding procedure is an effective method for treating dialysis-associated steal syndrome.". Kidney Int. 77 (4): 359–66. doi:10.1038/ki.2009.461. PMID 20010547.
- "Minimally Invasive Limited Ligation Endoluminal-assisted Revision (MILLER) for treatment of dialysis access-associated steal syndrome". Kidney International. 70 (4): 765–70. August 2006. doi:10.1038/sj.ki.5001554. PMID 16816841.
This article is issued from Wikipedia - version of the 6/2/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.